ALTAIR® 5X Multigas Detector

The ALTAIR 5X Gas Detector is capable of measuring up to 6 gases simultaneously and is now available with integrated PID sensor for VOC detection. Driven by advanced MSA XCell® Sensor Technology,  the ALTAIR 5X Gas Detector delivers  faster response time, better stability, accuracy, longer service life, and cost savings over the life of the instrument.

Dräger Pac 6500 Single Gas Detector

Dimensions (W x H x D)64 x 84 x 20 mm
WeightApprox. 106 g (113 g with clip)
Battery service life2 years (O2 sensors min. 10 months)
Protection classIP68
Air pressure700 to 1,300 hPa
Air humidity10 to 90% relative humidity, non-condensing
Temperature-30 °C to +55 °C (briefly down to -40 °C for 1 hr, depending on sensor)
ApprovalscCSAus, IECEx, ATEX, CE

Dräger Pac 8000 Single Gas Detector

Dimensions (W x H x D)64 x 84 x 20 mm
WeightApprox. 106 g (113 g with clip)
Battery service life2 years
Protection classIP68
Air pressure700 to 1,300 hPa
Air humidity10 to 90% relative humidity, non-condensing
Temperature-30 °C to +55 °C (briefly down to -40 °C for 1 hr, depending on sensor)
ApprovalscCSAus, IECEx, ATEX, CE

Dräger Pac 8500 Single Gas Detector

Dimensions (W x H x D)64 x 84 x 20 mm
WeightApprox. 106 g (113 g with clip)
Battery service life2 years (O2 and dual sensors min. 12 months))
Protection classIP68
Air pressure700 to 1,300 hPa
Air humidity10 to 90% relative humidity, non-condensing
Temperature-30 °C to +55 °C (briefly down to -40 °C for 1 hr, depending on sensor)
ApprovalscCSAus, IECEx, ATEX, CE

Dräger X-Am 2500 Multi Gas Detector

Dimensions (W x H x D)48 x 130 x 44 mm
WeightApprox. 220-250 g
Operating times> 12 h with alkaline and NiMH, >13 h with NiMH HC, > 250 h w/o Ex sensor with alkaline batteries
Protection classIP67
Air pressure700 to 1,300 mbar
Air humidity10 to 95% relative humidity, non-condensing
Temperature-20 °C to +50 °C
Charging time<4 hrs
ApprovalscCSAus, IECEx, ATEX, CE, MED

Dräger X-Am 5000 Multi Gas Detector

Dimensions (W x H x D)48 x 130 x 44 mm
WeightApprox. 220-250 g
Operating times> 12 hours with Alkaline and NiMH; > 13 hours with NiMH HC; without Ex Sensor typ. > 250 hours with Alkaline Battery; when using the Save Energy Mode > 40 hours
DataloggerRetrievable using an infrared interface > 1000 h with 4 gases at a recording interval of 1 value per minute
Protection classIP67
Air pressure700 to 1,300 mbar
Air humidity10 to 95% relative humidity, non-condensing
Temperature-20 °C to +50 °C
Charging time<4 hrs
ApprovalscCSAus, IECEx, ATEX, CE, MED

Fire Hoods

In addition to the jacket and trouser, a firefighter’s personal protection also depends on the careful selection of head, hand and foot protection. MSA Bristol supplies a range of flash hoods which have been carefully selected and tested for compatibility with the other garments to be used. A special compatibility area within our technical and design department allows firefighters to check the all-round suitability of the complete ensembles being selected for use. MSA Bristol offers a wide selection of hoods for structural, wilderness and USAR operations.