Dräger FPS 7000 Full Face Mask
| Mask body | Convenient, hypoallergenic and flexible silicone or EPDM (dermatologically tested) |
| Harness | 5-point harness with a large contact surface area at the back of the head, alternatively a hairnet |
| Mask-helmet combination | 2-point connection for Dräger HPS 7000 either with Dräger Qfix (with safety button) or with Dräger S-fix (without safety button) connectionSize |
| Size | Mask body in 3 sizes (S, M and L) compatible with inner mask in 3 different sizes |
| Visor | polycarbonate visor available with different coatings |
| Connector | P, RA, ESA, PE |
| Weight | Approx. 600 g (varies according to version) |
| Approval | > EN 136 Class. 3, EN 137 type 2, DIN 58610 (MHK), NIOSH (some versions) |
Dräger PAS Lite Breathing Apparatus
| Dimensions (H x W x D) | 23.2 x 11.4 x 6.3 inches (59 x 29 x 16 cm) |
| Weight (including LDV) | 5.95 lb. (2.70 kg) |
| Weight with Integrated PAS ASV (including LDV) | 7.72 lb. (3.50 kg) |
| Input Pressure | 2216 PSI, 4500 PSI |
| Nominal 1st Stage Output Pressure | 87-130 PSI |
| 1st Stage Output Flow | >1000 L/min |
| LDV Output Flow | >400 L/min |
| Whistle Activation Pressure | 554 PSI, 1125 PSI |
| Whistle Sound Level | >90 dBA |
| Approvals | NIOSH |
Dräger PSS 4000 Breathing Apparatus
| Weight Kg (Backplate and Harness) | 3kg / 3.38 kg with BG 1500 |
| Input Pressure (bar) | 0-300 |
| Nominal 1st Stage output pressure | 7.5 bar |
| 1st stage output flow (lit/min) | 1000 |
| LDV output flow (l/min) | Greater than 400 |
| Whistle activation pressure (bar) | 50-60 |
| Whistle Sound Level (dBA) | Greater than 90 and 102-112 with BG 1500 |
| Approvals | Approvals EN 137:2006, ATEX 94/9/EC (I M1/II 1GD EEx ia I/IIC T4) (Ta = -30 °C to +60 °C) (Type 2) |
Dräger PSS 5000 Breathing Apparatus
| Weight Kg (Backplate and Harness) | 3.85kg/ 4.6 kg with BG 7000 |
| Input Pressure (bar) | 0-300 |
| Nominal 1st Stage output pressure | 7.5 bar |
| 1st stage output flow (lit/min) | 1000 |
| LDV output flow (l/min) | Greater than 400 |
| Whistle activation pressure (bar) | 50-60 |
| Whistle Sound Level (dBA) | Greater than 90 and 102-112 with BG 7000 |
| Approvals | Approvals EN 137:2006 (Type 2) |
Dräger PSS 7000 Breathing Apparatus
| Weight of complete set with Dräger FPS® 7000 full-face mask, lung demand valve and Dräger 6.8 litre carbon composite cylinder, 20 year design life (kg) | 11.7kg with pneumatic guage/ 12.2 kg with BG 7000 |
| Input Pressure (bar) | 0-300 |
| Nominal 1st Stage output pressure | 7.5 bar |
| 1st stage output flow (lit/min) | 1000 |
| LDV output flow (l/min) | Greater than 400 |
| Whistle activation pressure (bar) | 50-60 |
| Whistle Sound Level (dBA) | Greater than 90 and 102-112 with BG 7000 |
| Battery(5xAA battery pack) | Greater than 365 hrs of normal use |
| Approvals | Approvals EN 137:2006,vfdb 0802,NFPA 1981:2018 ED (Ta = -30 °C to +60 °C) (Type 2) |
MSA G1 SCBA Remote Quick-Fill® System
MSA SSR 30/100 (Class 20) – Oxygen Self-Rescuer
MSA, Respirator Protection, Pok Fire UAE Supplier, Rescue, Self Contained Breathing Apparatus (SCBA)
PremAire® Escape
One-Piece Cylinder Valve and First Stage Pressure Reducer
- Reduces size and profile
- Protects gauge
- Reduces size and profile
- Convenient and fast refilling of the compressed air cylinder
- No restrictions in compressor filling pressure (200 or 300 bar)
- Ease of attaching QuickFill adaptor
- Rated duration of 15 or 20 minutes
- Two independent protecion barriers
- High protection factors in sour oil & gas and chemical applications
- Straightforward and easy donning
- Simplistic training requirements
- High visibility (orange hood)
- Base support provides protection for comp ressed air cylinder
- Ease of stacking in storage
- Fullfills the antistatic requirements of EN 402
- Increased safety
- Meets special requests for a low pressure warning
Markets: Fire Service, General Industry, Oil & Gas, Utilities
STORM EN136 EN137 6L STEEL, 6.8L CARBON FIBER GAS CYLINDER SCBA SUPPORTS CUSTOMIZED ACCESSORIES
SCBA is essential in environments with smoke, toxic gases, hot vapor, or low oxygen. It includes a lightweight, fireproof gas cylinder with a copper valve and an optional pressure display for real-time monitoring. The air supply system features a pressure reducer, air supply pipe, full face mask, demand valve, and gauge. Additional options like a hud display, fall alarm, and intercom enhance safety and communication.APPLICATIONS- Ideal for firefighters and rescue workers in toxic or hazardous environments.-Provides respiratory protection in smoke, gas, and low oxygen conditions.-Used in fire protection, power plants, chemical industries, shipping, smelting, warehouses, labs, and mining.SPECIFICATIONSGas Mask Visual Field: >96%Inhalation: 30L/minCylinder Material: Carbon Fiber+Aluminum alloyCylinder Capacity: 2040LExhalation Resistance: <1000PaInhalation Resistance: <500PaOperation Temperature: -30°-60°CAlarm Pressure: 5.5MpaWorking pressure: 30MpaService Time: 60minAlarm Sound: 90DBWeight: 13kgPacking: Plastic Case (black or Orange)